Ref. No. | Type | Max. output power | Family data sheet | Isolation primary - secondary | Length | Width | Height | Weight |
---|---|---|---|---|---|---|---|---|
186414 | ECXe 350.129 | 42 W | double or reinforced Isolation | 280 mm | 30 mm | 21 mm | 200 g | |
186429 | ECXe 700.140 | 60 W | SELV | 280 mm | 30 mm | 21 mm | 203 g |
Ref. No. | Type | Max. output power | Output current | Min. output voltage | Max. output voltage | Output ripple (100 Hz) | Output current tolerance – | Output current tolerance + |
---|---|---|---|---|---|---|---|---|
186414 | ECXe 350.129 | 42 W | 350 mA | 80 V | 120 V | 3 % | -5 % | 5 % |
186429 | ECXe 700.140 | 60 W | 700 mA | 46 V | 86 V | 3 % | -5 % | 5 % |
Ref. No. | Type | Max. output power | Min. voltage | Max. voltage | Min. input voltage AC | Max. input voltage AC | Min. mains frequency | Max. mains frequency | Input current at 230 V AC with max. load | Power factor at full load (230 V) | Efficiency at full load (230 V) | THD at full load (230 V) | Inrush current | Inrush current time at 50% Ipeak |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
186414 | ECXe 350.129 | 42 W | 220 V | 240 V | 198 V | 264 V | 50 Hz | 60 Hz | 200 mA | 0.9 | 0.88 | 10 % | 21 A | 137 µs |
186429 | ECXe 700.140 | 60 W | 220 V | 240 V | 198 V | 264 V | 50 Hz | 60 Hz | 275 mA | 0.9 | 0.89 | 10 % | 22.4 A | 135 µs |
Ref. No. | Type | Max. output power |
---|---|---|
186414 | ECXe 350.129 | 42 W |
186429 | ECXe 700.140 | 60 W |
Ref. No. | Type | Max. output power | Dimmable | DALI power supply integrated | DALI power supply switchable |
---|---|---|---|---|---|
186414 | ECXe 350.129 | 42 W | No | No | No |
186429 | ECXe 700.140 | 60 W | No | No | No |
Ref. No. | Type | Max. output power | Isolation primary - secondary | Open circuit voltage (Umax.) | Protection against transient main peaks L–N | Protection against transient main peaks L/N–PE | Leakage current over PE |
---|---|---|---|---|---|---|---|
186414 | ECXe 350.129 | 42 W | double or reinforced Isolation | 130 V | 1 kV | 2 kV | 0.5 mA |
186429 | ECXe 700.140 | 60 W | SELV | 95 V | 1 kV | 2 kV | 0.5 mA |
Ref. No. | Type | Max. output power | EU Declaration of Conformity |
---|---|---|---|
186414 | ECXe 350.129 | 42 W | |
186429 | ECXe 700.140 | 60 W |
Ref. No. | Type | Max. output power | 2D data | 3D data |
---|---|---|---|---|
186414 | ECXe 350.129 | 42 W | ||
186429 | ECXe 700.140 | 60 W |
Ref. No. | Type | Max. output power |
---|---|---|
186414 | ECXe 350.129 | 42 W |
186429 | ECXe 700.140 | 60 W |
Ref. No. | Type | ||
---|---|---|---|
186414 | ECXe 350.129 | ||
186429 | ECXe 700.140 |
Ref. No. | Type | 2D data | 3D data |
---|---|---|---|
186414 | ECXe 350.129 |
|
|
186429 | ECXe 700.140 |
|